If a cable tester prints PASS at both ends of a run, most installers stop thinking about the copper. I do the opposite. A pass tells me the eight conductors land where they should and that nothing is shorted. It tells me almost nothing about whether that pair will hold up at 600 mA on a warm afternoon. Those are two different questions, answered by two different instruments, and the space between them is where a surprising share of PoE faults hide.
Last week I was in a warehouse in Bao'an with fourteen cameras spread over three switches. All twenty-two links had been certified a month earlier and the report was clean: no opens, no split pairs, lengths between 61 and 88 m. Two of those cameras still rebooted every evening around 19:10, right when the IR illuminators kicked in and the loading dock doors started cycling. Nobody had touched the cable since the report. The tester was not lying. It simply was not answering the question we needed answered.
What a wiremap test actually proves
A handheld wiremap test pushes a very small current down each conductor and watches where it comes back. On most of the sub-hundred-dollar units that current is around a milliamp, sometimes less, because the whole point is to light an LED without cooking anything if the far end is miswired. Continuity, pin-to-pin mapping, no shorts between pairs. That is the test.
Now put a splice in the middle of a run. Not a broken splice — a lazy one, a punch-down that grabbed two strands instead of six, a coupler with corroded contacts. Call it 1.8 Ω of extra resistance on one conductor. At 1 mA that extra resistance produces 1.8 mV of drop. Your tester sees nothing, because there is nothing to see at that current. At 0.6 A the same 1.8 Ω costs 1.1 V, and if the fault sits on a conductor carrying half the port current, closer to 0.5 V. Two lazy terminations and you have burned a volt on a link that passed twice.
Wiremap also says nothing about how the pairs are twisted. A run untwisted for the last 40 mm at a jack passes wiremap, passes length, then falls over at gigabit under load — a data problem that arrives at the same camera and gets blamed on the same switch.
Length is a clock reading, not a ruler
Every tester that reports length is doing time-domain reflectometry: it fires a pulse, waits for the reflection, and divides by a number you never see, the nominal velocity of propagation. Copper does not carry a signal at the speed of light. It carries it at somewhere between 0.64c and 0.72c depending on the dielectric, and the tester assumes a value for the cable category you told it you were testing.
The arithmetic is not complicated. Length equals half the round-trip time multiplied by NVP times c. If your tester assumes 0.70 and the cable in the wall is really 0.66 — a different dielectric compound, a batch that drifted — every reading comes out about six percent long. The reel said 90 m. The tester says 95.5 m. Both numbers are honest, and the one that matters for voltage drop is neither.
Length also has no fixed relationship to resistance. Seventy metres of 26 AWG has more copper resistance than ninety metres of 23 AWG. I have watched people reject a 92 m run as "too long" and accept a 78 m run that was worse, because nobody read the gauge printed on the jacket. The limits that matter are in the cable gauge versus loop resistance comparison, not on the length screen.
The number that actually decides your voltage
What you want to know is loop resistance: how many ohms the current will see on its way out and back. A certifier prints this per pair, which means both conductors of that pair in series. For 100 m of 24 AWG solid copper at 20 °C that is about 18.8 Ω, and it is the figure worth memorising because everything else scales off it.
Here is the part that trips people up. On a two-pair PoE link, power leaves on one pair and returns on the other, so the two pairs sit in parallel from the current's point of view. The copper the PD actually sees is half the per-pair figure — roughly 9.4 Ω per 100 m on 24 AWG, not 18.8. That is the whole reason 802.3at can lose 4.5 W in the cable and still land 25.5 W at the device.
And that 4.5 W is where the famous 12.5 Ω budget comes from: 4.5 W divided by 0.6 A squared. It is not a copper measurement. It is a number the standard picked so a compliant channel — copper, jacks, patch cords, a temperature allowance — still delivers the promised wattage. Measured 24 AWG at 45 °C sits near 10.3 Ω; two 3 m 28 AWG patch cords add 1.3 Ω more. The budget is not generous, it is just honest about terminations. I went through the jack end of this in the 12.5 Ω channel budget walkthrough, and the short version is that the last two metres are frequently the worst.
| Conductor | Ω per conductor, 100 m, 20 °C | Pair loop (2 in series) | PoE 2-pair path at 45 °C | Drop at 0.6 A |
|---|---|---|---|---|
| 23 AWG | 7.5 Ω | 15.0 Ω | 8.2 Ω | 4.9 V |
| 24 AWG | 9.38 Ω | 18.8 Ω | 10.3 Ω | 6.2 V |
| 26 AWG | 13.4 Ω | 26.8 Ω | 14.7 Ω | 8.8 V |
| 28 AWG | 21.4 Ω | 42.8 Ω | 23.5 Ω | 14.1 V |
Copper resistance rises 0.393 % per °C, so the 45 °C column is 9.8 % above the 20 °C one. The 28 AWG row is patch-cord territory: nobody runs it 100 m, but a 3 m cord at each end still costs 1.3 Ω.
One line worth keeping on your phone:
V at the device = V at the port − (current × loop resistance)
An 85 m 24 AWG run at 42 °C, feeding a 30 W port: loop resistance lands near 8.7 Ω, and at 0.6 A that is 5.2 V gone. Start at 52.5 V and the camera sees 47.3 V. Comfortable. Now do the same run with 26 AWG patch cords, two couplers and a jack that was punched down twice, and the same camera sees 43 V. An 802.3at PD shuts off below 42.5 V. That is a 0.5 V margin on a link that passed certification without a single flag.
Balance: the number that never gets printed
Inside a pair, the two conductors should have the same resistance. When they do not, the common-mode current that PoE deliberately sends down the pair splits unevenly. The result is a small differential voltage across a pair that is supposed to be balanced — noise on the data path, retransmissions, and on four-pair 802.3bt, one pair set carrying more than its share and running hotter than its neighbours.
Most reports exclude it unless you select a limit set with PoE measurements switched on. On the certifiers that support them, intra-pair and inter-pair unbalance are optional extras, not part of the default pass. A report can be entirely clean and say nothing about the thing that is failing.
The field test is crude but effective. If you have per-pair resistance, compare the four. If one pair is more than a few percent above the others, stop and go find the jack. It is almost always the jack. I pulled three terminations this year where the punch-down tool had been set for a different blade and nicked one side of a pair; the pair read 11 Ω against 9.2 Ω on its neighbours, wiremap was green, and the camera worked fine until the IR came on.
Why you cannot just touch a multimeter to a PoE port
People try this constantly, and the result is confusing in both directions. A good port that is not currently powering anything reads 0 V, because the PSE will not apply voltage until it has seen a valid PD signature — the 25 kΩ resistor I walked through in the detection and classification walkthrough. A multimeter is 10 MΩ. It does not look like a powered device. The port correctly refuses to energise.
A port that is powering something reads somewhere between 48 and 54 V if you can get a probe onto it, but that number is open-circuit voltage at the PSE, not what the camera is receiving. It tells you the port works. It tells you nothing about the cable, which is the part you suspect.
To see loaded voltage you need something that draws a controlled current and passes detection. Two options that work: a PoE tester that emulates a PD at a known class, or the actual device with an inline meter. The first is faster and repeatable; the second is the truth. Either way you want a pair of readings, port and device, because the difference divided by the measured current gives you the real loop resistance of that run, terminations included. No report will hand you that number.
Worth saying out loud: a cheap tester with a "PoE" LED that lights above roughly 40 V cannot tell a healthy 53 V port from one that will collapse to 41 V under load. Both light the LED. This is why I keep a load bank on the bench. If you want the port-side view of the same question, the per-port power reading on a managed PoE switch is coarse but free, and it is measured at the source rather than at the far end — exactly what you need when comparing two numbers.
A bench routine that catches what the report misses
This is the sequence I run on any link that will carry more than 15 W, or where someone has already replaced a camera once. It has saved me more return visits than any instrument I have bought.
- Certify with a PoE limit set, not the default. If your tester has an option that adds loop resistance and resistance unbalance, turn it on before the first test, not after the complaint.
- Write down all four pair resistances. Not just pass or fail. The spread between pairs is the early warning, and a report that only says PASS throws that away.
- Measure at the port and at the device, under real load. IR on, heater on, whatever the worst case is. Open-circuit voltage at either end is not a measurement of the cable.
- Do the division yourself. Port voltage minus device voltage, divided by the current the switch reports for that port. That is the loop resistance of the installed link, jacks and cords included. On a clean 85 m 24 AWG run expect 8 to 9 Ω; anything over 12 means terminations.
- Hold the load for twenty minutes. Resistance climbs with temperature, and a link that passes cold can sit right on the 42.5 V line once the copper warms up and the ambient peaks.
- Compare the port's delivered wattage against the class reservation. If the switch reserved 30 W and is delivering 6 W, the port is not the problem and you are looking in the wrong place.
- Keep the numbers with a date and the cabinet temperature. Half the value is in the second visit, when you can see that the same link read 9.1 Ω in March and 11.4 Ω in August.
Questions I get asked at the bench
Will a continuity tester damage a live PoE port?
Some will, or will be damaged themselves. Cheap units are not all rated for 57 V, and a test current into an energised port gets you a meaningless reading or a dead tester. Test dead links dead. If the link is live and you need to test it, use something designed for it.
So is a basic tester useless?
No. It is excellent at three things: finding which cable in a bundle is which, confirming a re-termination took, and telling you a run is open. That covers half of all cabling faults. It is just not a PoE instrument, and a PoE badge on the box does not change that.
My tester says 802.3at, but the camera only pulls 15 W. Why?
The tester is usually reporting what the PSE advertises, or simply that it saw more than 50 V. The class comes from the resistor inside the device, and a Class 4 camera that is idling will sit at 4 W all day. Advertised capability, negotiated class and actual draw are three different numbers, and confusing them is how people buy a bigger switch they did not need.
Can I skip the tester and use the switch's port statistics?
Mostly yes, for the power half of the question. Per-port wattage gets you the loaded current and a rough idea of what the device is doing. It cannot tell you where the loss is happening, because it measures at the source. Use it to prove the port is fine, then go measure at the far end.
How long should a link run before I sign it off?
Long enough for the worst-case load to happen. Twenty to thirty minutes with the IR on and the cabinet closed. If the site has a daily peak, come back for it. The two cameras in Bao'an only failed between 19:05 and 19:20, and no amount of testing at 11 a.m. was ever going to reproduce that.
What eventually fixed those two runs was not a setting. We pulled the far-end jacks, found one with two strands under the blade and one with the pair untwisted down to the crimp, re-terminated both, and the evening reboots stopped. The certification report was still correct. It had simply measured a different property than the one that was failing, at a current three orders of magnitude below the one doing the damage.
I still do not have a clean explanation for a run last spring that passed everything — certification, loaded voltage, twenty-minute soak — and then dropped a camera every time the three-phase motor on the packing line started. Best guess is common-mode noise coupling into an unshielded run beside a poorly bonded conduit. We moved the run and the fault went away, which is satisfying as a repair and unsatisfying as an explanation. If you have chased something similar and actually proved the mechanism, I would like to hear how, because a green light and a working camera are still not the same evidence.